Abstract    Water cooling by ambient takes place with two mechanisms of heat and mass transfer. Using packings at wet cooling towers has disadvantages such as obstruction, reduction of life expectancy and production of algae and fungi. In shower cooling towers types of towers packings are completely removed and water intake is in direct contact and heat transfer takes place in two ways of latent and sensible. In this article mathematical modeling and simulation of towers has been done using differential equations. Differential equations derived using the laws of conservation of mass and energy. Differential equations is solved in a computer program for numerical solution. The operation of shower cooling towers at different environmental conditions was observed. These towers in the area of cold, dry, warm and dry possess high efficiency. In very hot areas by reducing the drops diameter, the tower outlet temperature can be improved.

 

Keywords    Shower Cooling Tower, Heat transfer, Mass transfer

 

چکیده    عمل سرمایش آب توسط هوای محیط بادومکانیزم انتقال حرارت وجرم صورت می­گیرد. وظيفه برج­های خنك­كن، جذب گرما از یک فرايند ودفع آن به فضايا اتمسفر است. استفاده از پکینگ ها در برج های خنک کننده تر دارای معایبی ازجمله انسداد مسیر، کاهش طول عمر و تولید جلبک ها و قارچ می باشد. نوع جدیدی از برج ها که به برج خنک کننده بارشی معرف است در آن پکینگ ها بطور کامل حذف و آب در تماس مستقیم هوای ورودی قرارگرفته و انتقال حرارت به دو صورت نهان و محسوس انجام می­پذیرد. در این مقاله مدل سازی ریاضی و شبیه سازی برج­ها با استفاده معادلات دیفرانسل حاکم انجام گرفته است. معادلات دیفرانسیل با استفاده قوانین بقای جرم و انرژی بدست آمده و با یک برنامه کامپیوتری به حل عددی پرداخته و عملکرد برج خنک کننده بارشی در شرایط مختلف محیطی بررسی شده است. این برجها در ناحیه سرد و خشک و گرم و خشک دارای راندمان بالایی می­باشد. در نواحی بسیار گرم با کاهش قطر قطره می توان دمای خروجی از برج را بهبود بخشید.

References   

1.     Ning, T., Chong, D., Jia, M., Wang, J. and Yan, J., "Experimental investigation on the performance of wet cooling towers with defects in power plants", Applied Thermal Engineering,  Vol. 78, (2015), 228-235.

2.     Ilhan-Sungur, E. and Çotuk, A., "Microbial corrosion of galvanized steel in a simulated recirculating cooling tower system", Corrosion Science,  Vol. 52, No. 1, (2010), 161-171.

3.     Merkel, F., "Verdunstungskfjhlung", VDI Forschungsarbeiten,  No. 275.

4.     Yajima, S. and Givoni, B., "Experimental performance of the shower cooling tower in japan", Renewable Energy,  Vol. 10, No. 2-3, (1997), 179-183.

5.     Givoni, B., "Performance of the “shower” cooling tower in different climates", Renewable Energy,  Vol. 10, No. 2-3, (1997), 173-178.

6.     Qi, X., Liu, Z. and Li, D., "Performance characteristics of a shower cooling tower", Energy conversion and management,  Vol. 48, No. 1, (2007), 193-203.

7.     Qi, X., Liu, Z. and Li, D., "Numerical simulation of shower cooling tower based on artificial neural network", Energy Conversion and Management,  Vol. 49, No. 4, (2008), 724-732.

8.     Qi, X., Liu, Z. and Li, D., "Prediction of the performance of a shower cooling tower based on projection pursuit regression", Applied Thermal Engineering,  Vol. 28, No. 8-9, (2008), 1031-1038.

9.     Muangnoi, T., Asvapoositkul, W. and Hungspreugs, P., "Performance characteristics of a downward spray water-jet cooling tower", Applied Thermal Engineering,  Vol. 69, No. 1-2, (2014), 165-176.

10.   Qi, X., Liu, Y., Guo, Q., Yu, J. and Yu, S., "Performance prediction of seawater shower cooling towers", Energy,  Vol. 97, (2016), 435-443.

11.   Mickley, H.S., "Design of forced draft air conditioning equipment", Chemical Engineering Progress,  Vol. 45, No. 12, (1949), 739-745.

12.   Givoni, B. and Al-Hemiddi, N., Applicability of a``shower``passive cooling tower in a hot dry climate. 1995, American Solar Energy Society, Boulder, CO (United States).


Download PDF 



International Journal of Engineering
E-mail: office@ije.ir
Web Site: http://www.ije.ir